Harnessed cables suitable for FANUC
readycable® power cable suitable for Fanuc LX660-8077-T296, base cable PVC 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- CFRIP®
- chainflex® class: 5.5.2.1











readycable® brake cable suitable for Fanuc LX660-8077-T311, base cable PUR 6.8 x d
- Requirements: For heavy duty applications
- Outer jacket: PUR
- Overall shield
- Coolant resistant
- Notch-resistant
- Hydrolysis and microbe-resistant
- Flame retardant
- Halogen-free
- Silicone-free
- UV-resistant
- PVC-free
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- CFRIP®
- chainflex® class: 5.5.3.1














readycable® power cable suitable for Fanuc LX660-8077-T296, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Notch-resistant
- Overall shield
- PVC-free
- chainflex® class: 4.2.3.1














readycable® power cable suitable for Fanuc LX660-8077-T296, base cable PUR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Notch-resistant
- Overall shield
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® power cable suitable for Fanuc LX660-8077-T296, base cable TPE 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Hydrolysis and microbe-resistant
- Flame retardant
- Silicone-free
- UV resistance: High
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class: 6.6.4.1












readycable® power cable suitable for Fanuc LX660-8077-T298, base cable PVC 7.5 x d
- Requirements: For heavy duty applications
- Outer jacket: PVC
- Overall shield
- Flame retardant
- Silicone-free
- UV resistance: Medium
- Oil resistance: Oil-resistant according to DIN EN 50363-4-1
- CFRIP®
- chainflex® class: 5.5.2.1











readycable® signal cable suitable for Fanuc LX660-4077-T302, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- chainflex® class: 4.2.3.1














readycable® power cable suitable for Fanuc LX660-8077-T298, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Notch-resistant
- Overall shield
- PVC-free
- chainflex® class: 4.2.3.1














readycable® power cable suitable for Fanuc LX660-8077-T298, base cable TPE 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Overall shield
- Hydrolysis and microbe-resistant
- Flame retardant
- Silicone-free
- UV resistance: High
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- CFRIP®
- chainflex® class: 6.6.4.1












readycable® signal cable suitable for Fanuc LX660-4077-T302, base cable TPE 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: TPE
- Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA
- Halogen-free
- Silicone-free
- Hydrolysis and microbe-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.6.4.1











readycable® signal cable suitable for Fanuc LX660-4077-T297, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- chainflex® class: 4.2.3.1














readycable® power cable suitable for Fanuc LX660-8077-T298, base cable PUR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Notch-resistant
- Overall shield
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1















readycable® signal cable suitable for Fanuc LX660-4077-T296, base cable PUR 10 x d
- Requirements: For medium duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- chainflex® class: 4.2.3.1














readycable® signal cable suitable for Fanuc LX660-4077-T297, base cable PUR 7.5 x d
- Requirements: For extremely heavy duty applications
- Outer jacket: PUR
- Oil resistance: Oil-resistant according to DIN EN 50363-10-2
- Halogen-free
- Silicone-free
- Flame retardant
- Offshore
- Coolant resistant
- Hydrolysis and microbe-resistant
- Overall shield
- Notch-resistant
- PVC-free
- CFRIP®
- chainflex® class: 6.5.3.1